MASS User Documentation

  • Home
  • Help Files
    • Getting Started
      • Introduction to MASS
      • Installation Guide
      • Activation Guide
      • Computer Requirements
      • Where to Get Help
      • What’s new in Version 4.0?
        • Version History and Change Log
    • Getting to Know MASS
      • General Overview
      • Assemblage Modules
      • Creating a Project File
      • Adding, Renaming, and Removing
      • Saving a Project File
      • User Interface Overview
      • Design Steps
      • A Complete Design
      • Analysis
      • Printing
      • Masonry Unit Database
    • Beams
      • Introduction
      • Design Steps
      • A Complete Design
      • Design Strategy
    • Out-of-Plane Walls
      • Introduction
      • Design Steps
      • A Complete Design
      • Loads Analysis Results
      • Design Strategy
      • P-M Interaction Diagram
    • Shear Walls
      • Introduction
      • Design Steps
      • Boundary Elements
      • A Complete Design
      • Load Analysis Results
      • Design Strategy
      • Element Deflection
      • Self-Weight
      • Interaction Diagram
    • Multi-Storey Shear Walls
      • Introduction
      • Design Steps
      • Design Strategy
      • Load Distribution
      • Drift
    • Shearline
      • Introduction
      • Design Steps
      • Load Distribution
      • Pier Generation
      • Design Strategy
  • Contact Us

Bug Notification

Bug Notification

Notification: Seismic Shear Forces Amplification Change for Elements Above Critical Section

The storey-by-storey design approach currently in MASS can excessively amplify shear forces beyond expected results   In cases where a bug or other issue is found in the MASS software, announcements are posted on the software’s known bugs page, as well as on this page here. It is always encouraged Read more…

By Brad Crumb, 1 month1 day ago
Bug Notification

Bug Notification: Non-Seismic Lateral Companion Loads Amplified for Seismic Effects

Be aware of this for shear wall designs resisting lateral earth pressures   In cases where a bug or other issue is found in the MASS software, announcements are posted on the software’s known bugs page, as well as on this page here. It is always encouraged that suspected bugs Read more…

By Brad Crumb, 2 months3 weeks ago
Bug Notification

Bug Notification: Out-of-Plane Shear Resistance checked only at location of maximum shear

While not always calculated at the critical location of a wall, out-of-plane walls are typically governed by flexure.   In cases where a bug or other issue is found in the MASS software, announcements are posted on the software’s known bugs page, as well as on this page here. While Read more…

By Brad Crumb, 5 months3 months ago
Bug Notification

Known Bugs in MASS

Bugs are found from time to time and in our effort to be trustworthy and transparent, they are posted here as well as appearing on the MASS Welcome Screen   The known bugs page has moved from the MASS website to the MASS section of the CMDC website. Click here Read more…

By Brad Crumb, 5 months2 weeks ago
Bug Notification

MASS Bug Notification: Maximum Allowable Axial Load Overestimated for some Shear Walls with Fully Grouted Flanges

Understanding the issue, when it can come up, and what can be done to account for it When software bugs are found, notifications are posted in the Known Bugs page, on the MASS welcome screen, as well as here on the CMDC website software blog in an effort to be transparent Read more…

By Brad Crumb, 1 year2 months ago
Bug Notification

MASS Bug Notification: Software Crashes Unexpectedly

Ever had MASS stop working while working on a design? You aren’t alone! In any windows architecture application, there is a limit of 10,000 GDI objects. Internally, there a number of these crated with every design and population of each results screen. Unfortunately, there are a number of these that Read more…

By Brad Crumb, 1 year ago
Bug Notification

MASS Bug Notification: Saved Projects and French Canadian Language Settings

Depending on keyboard or Windows system settings, it is possible to re-open a project file and see different results Have you ever saved a MASS file you were working on, only to open it up a few days later to see some values that are orders of magnitude larger? If Read more…

By Brad Crumb, 1 year3 months ago
Bug Notification

MASS Bug Notification: Critical buckling load overestimated for some reinforced walls under high axial load

Understanding the issue, when it can come up, and what can be done to account for it   This article originally was featured on the MASS Software Blog, formerly hosted on the software section of the Canada Masonry Design Centre website. CMDC is the authorized technical service provider for the Read more…

By Brad Crumb, 4 years3 months ago
Recent Posts
  • Notification: Seismic Shear Forces Amplification Change for Elements Above Critical Section
  • Bug Notification: Non-Seismic Lateral Companion Loads Amplified for Seismic Effects
  • Version 4.0 Feature Spotlight: Ductility Verification
  • Version 4.0 Feature Spotlight: Simplified National Building Code Seismic Design
  • Bug Notification: Out-of-Plane Shear Resistance checked only at location of maximum shear
  • Known Bugs in MASS
  • MASS Version 4.0 is now available – adds multi-storey design and more earthquake design options
  • MASS Version 4.0 Release Notification
  • Version 4.0 Feature Spotlight: Online Activation Restored!
  • Why doesn’t MASS consider Type 6 Structural Irregularities?
Archives
Categories
  • Home
  • Installation
  • Activation
  • Beams
  • Walls
  • Shear Walls
  • Multi-Storey
  • Shearline
  • Contact Us
Hestia | Developed by ThemeIsle